| Specifications:
|
| Standard: |
ISO 11898 IEEE 802.3 |
| Ports: |
1 x RS485 1 x RS232
|
| Max Distance: |
ModBUS: 1200 m for 115k bps
RS232:
15 m max.
|
| Data Rates: |
ModBUS: up to 115k bps
|
| Isolation: |
>2000 VDC |
| LED: |
1 for power, 1 for data in RS485
1 for clock |
| Power: |
24 VDC 200mA
12/18V AC; 50/60 Hz;200mA |
| Temperature: |
Operating: -15° to +70° (5°F +158°F)
Storage: -20° to 80° (-4°F to 176°F) |
| Humidity: |
Operating:10% to 80%, non-condensing
Storage: 5% to 90%, non-condensing |
| EMI Compliance: |
EN 61000-6-2
FCC part 15 of Class A |
| Dimensions: |
120x23x107 (DxWxH) |
| Weight: |
200 g approx |
| Mechanical Fixing: |
DIN Rail montage |
| Software: |
SW67112 SW67113
|
|
|
|
|
Ordering Information:
| Datalogger: | |
| Datalogger ModBUS RTU Master |
HD67112 |
|
| Datalogger ModBUS RTU Slave |
HD67113 |
|
|
| Accessories: |
| DataLogger Configurator |
SW67112 |
| DataLogger Configurator |
SW67113 |
| Supply Power |
AC34001 |
| Supply Power |
AC34002 |
| | |
|
|